Look 4 an adaptor at rv store 4th prong is a ground
Always have your system serviced by a lic professional once every year or two ..try to use the same person and you both get to no your unit ..heaters have a delay on heat that allows the duct to heat a lil before fan runs ...there are many different mechanisms that control this task ....remember … Read more
Normal size 30 amp ..the max size for the appliance is labeled on its rating plate
I keep them ....but ill let others play with them to ... Last christmas ...i got a tranquilizer gun ..works great for dating !
If you are on a well there is a psi adjustment at the holding tank , ..if on city water ,a pressure reducing valve at the meter may be necessary... Problem is only at certain areas in the house try closing the cut off valve, under the sink a little... Good luck
A kilowatt is 1000 watts the formula is volts x watts = amps... Of volts ,amps ,watts ,.any two multiplied = the third
There are many parts to the ice maker ,I would try this first make sure the lever is pushed down ...take the plastic cover off the front, you will see gears take a small common screw driver or nut driver and turn the gear manually it should start the defrost cycle, the gears will start moving … Read more
The cut off valve or the tank fillvalve has a loose wash.etc replacing them should fix your water hammer problem
Don't understand question ... But going to make a stab anyway forgive me if I'm off base ...a gas can accumulate in a barely used water heater.... Hydrogen and it is explosive... Running water a while in a vented area will solve gas smell .. Cloudy water most of the time ,is caused by calcium deposits in … Read more
People had to use bowels, or go to the outhouse before,...in the beginning of indoor plumbing ,many contraptions were devised but sanitation was still a problem,john crapper invented the modern water closet ,we use today. It included an interocular trap for sewer gases a nonporous ,porcelain surface , and tank with water feed protection .the greatest reason though … Read more
Wow! Don't have enough space for that awns er, but in the short version,. " its just a matter of time ".. Its inevitable... Generally about the time ,when friends start becoming important ,defiantly by the drivers license age , but don't panic ,every child goes through a RE PARENTING phase,, into early 20's sometimes. Its only dangerous … Read more
Boiler is a self-contained appliance, specifically for heating fluids, in oklahoma under international building code, any fluid heating appliance, with 500,000 BTU input, or greater is labeled a boiler and is governed by specific rules.
A pressure vessel is a container designed to hold gas or liquid at a designed pressure and temperature, different from the ambient … Read more